Scan2CAD.online

FLOOR PLAN BENCHMARK · 2026

One floor plan.
How editable is your CAD?

One floor plan, 10 external tools and Scan2CAD.online free conversion, plus an internal AI sample. Compare editable text, arcs, layers and downloadable DXF evidence.

Results apply to this date, input file and the platform versions available at the time. Features, allowances and algorithms may change.

Customer-supplied imageEnlarge ↗
Customer-supplied imageSame input · 1080 × 2400
Our free conversionEnlarge ↗
Our free conversion24 TEXT · 6 ARC
AI reconstruction · internalEnlarge ↗
AI reconstruction · internal70 TEXT · 13 layers

Previews fit their respective extents and are not coordinate-aligned. Enlarge to inspect. SVGs illustrate DXF entities; font rendering may differ in CAD.

WHAT THE FILES SHOW

Evidence you can inspect

10

External free tools

9 outputs contain outlines; 1 has no renderable geometry. None contains TEXT or ARC in this test.

24

Editable text entities in our free output

Alongside 842 LINE and 6 ARC entities. OCR errors remain, and scale needs calibration.

13

Layers in the internal AI sample

Including WALL, DOOR and WINDOW. More explicit organization; accuracy still needs separate verification.

COMPARE THE STRUCTURE

CAD editability scores for this sample

Up to 10 points per criterion, 50 total. Follow each tool name to the evidence. This is not an accuracy percentage, traffic ranking or a prediction for other drawings.

10 external platforms + Scan2CAD free + internal AI
Tool / engineStructureContentUnits / refsText entitiesCAD organizationTotal
Scan2CAD.online AI · internal101010101050/5050/50
Scan2CAD.online free1010010535/5035/50
PolygonLogix101060026/5026/50
Nasji101030023/5023/50
StencilCut101030023/5023/50
Flip3D101030023/5023/50
TechDraw AI101030023/5023/50
Convertio101000020/5020/50
AnyConv101000020/5020/50
ImageToDXF101000020/5020/50
AnyDocFlow101000020/5020/50
Aspose.Imaging10000010/5010/50
Scoring rules & unverified checks

Structure: parsable DXF, 10 points. Content: renderable geometry, 10. Text: TEXT entities present, 10, without measuring OCR accuracy. CAD organization: fitted LINE/ARC/CIRCLE, 5, plus floor-plan semantic layers, 5.

Units / references: absent or unusable, 0; millimetres declared but extents disagree, 3; millimetres with one axis within 5% of the reference, 6; millimetres and documented overall references on both axes, 10. AI points use its 1:1 and 10,300 × 15,900 annotations, not measured wall-by-wall accuracy.

All results: text accuracy, dimensional error, wall connectivity, target-CAD opening and AUDIT have not received dedicated validation.

01 / EXTERNAL FREE TOOLS

Start with the ten external free outputs

“Free” describes the test path used to obtain these outputs. Allowances, login and pricing can change. No third-party traffic ranking is claimed.

EXTERNAL TOOL

Aspose.Imaging

Aspose.Imaging DXF structure preview from the same sampleEnlarge ↗
10/50Editability score0TEXT0ARC

This downloaded file has no renderable geometry; this does not establish failure on other inputs.

Entities: 0 · Layers: 0

02 / SCAN2CAD.ONLINE

Then compare our free engine and internal AI

We provide both outputs. The free result came from our public conversion endpoint. The AI file was supplied internally; its production process was not independently audited and cleanup time was not measured.

OUR FREE ENGINE

Scan2CAD.online free

Scan2CAD.online free DXF structure preview from the same sampleEnlarge ↗
35/50Editability score24TEXT6ARC

24 editable TEXT entities; false OCR and merged labels remain. Source-pixel units require scale calibration.

Entities: 1310 · Layers: 3

INTERNAL AI

Scan2CAD.online AI · internal

Scan2CAD.online AI · internal DXF structure preview from the same sampleEnlarge ↗
50/50Editability score70TEXT9ARC

70 TEXT, 9 ARC, 13 layers. Millimetres and overall dimensions are documented in the file; engineering accuracy is unverified.

Entities: 222 · Layers: 13

See what happens with your drawing.

Convert for free, inspect the text, lines and scale, then request an assessment if needed.

REPRODUCIBLE EVIDENCE

Method and public evidence

Test date: 2026-09-21. The ten external platforms and our free converter used the same customer-supplied PNG. The customer permitted public display and download of the sample and results. The AI file is a customer-supplied internal output shown as a separate reference group.

External outputs were audited as downloaded, without manual cleanup. We compared DXF versions, entity types, layers and units on this single sample. Our free engine was editable-drawing-v5.0. Previews may not show all text; inspect the DXF in your target CAD application.

Checks still pending

Text correctness: pending character-by-character review. Dimensional error: pending measurement against reliable references. CAD opening and AUDIT: pending checks in the target application. Structural scores do not replace these checks.

Questions before choosing a tool

Can I edit the text after free image-to-DXF conversion?

It depends on the entities. The 10 external outputs have no TEXT entities; our free output contains 24, with OCR errors. Letter outlines and editable text are different results.

Does the converted drawing have accurate millimetre dimensions?

No. Image pixels, declared millimetres and engineering scale are different things. Calibrate using known dimensions and check both axes. Millimetre annotations in the AI sample are not engineering acceptance.

Do 35/50 and 50/50 mean conversion accuracy?

No. Scores cover file structure, renderable content, units and reference information, text entities and CAD organization in this sample. Text accuracy, dimensional error and target-CAD import have not been quantified.

Can I use the internal AI engine now?

The AI result is an internal sample, not a promise of a publicly available instant service. Try the free converter first, then request an assessment for further work.